━ FIRE ALARM SYSTEMS · INSTALLATION & AMC
Fire alarm systems that get tested, not just installed.
Design, supply, installation and commissioning of conventional and addressable systems — then scheduled maintenance and four-hour fault rectification when the panel complains.
● New installations ● Annual maintenance ● Fault rectification ● 4-hour response
Survey & design
Building walk, risk review, device layout…
Installation
Containment, cabling, device mounting…
Commissioning
Every device tested in the zone it…
Supply
Panels, detectors, call points, sounders…
Programming
Cause-and-effect set up and tested — what…
Handover
As-built drawings, test results, staff…
COMPLIANCE & STANDARDS
✓Device-by-device test
✓As-built drawings
✓Staff Training
✓Handover
SYSTEM TYPES
Conventional or addressable — which one your building needs.
The choice is driven by size, floor count and how fast you need to locate the fire. We will tell you when the cheaper option is genuinely enough.
Conventional Fire Alarm System
-
Pinpoints the device: Identifies the affected zone only; manual searching is required to locate the specific device.
-
Best for: Small buildings, single-floor premises, and projects with limited budgets.
-
Wiring: Radial zone circuits, with multiple detectors and call points connected to each zone.
-
Adding devices later: Limited by the zone capacity and available circuit capacity.
-
Typical maintenance: Zone-by-zone testing, detector cleaning, and checking zone wiring and end-of-line devices.
Addressable Fire Alarm System
-
Pinpoints the device: Identifies the exact device by its unique address, making fault and alarm location easier.
-
Best for: Large buildings, multi-storey facilities, industrial sites, and complex premises.
-
Wiring: Loop-based circuits, with multiple addressable devices connected to a common communication loop.
-
Adding devices later: More flexible; additional devices can be added subject to loop capacity and system compatibility.
-
Typical maintenance: Individual device testing, detector cleaning, checking device addresses, loop integrity, communication status, and system fault history.
NEW INSTALLATION
What we do between survey and handover.
One team from design to commissioning, so nothing is handed between contractors mid-project.
Survey & design
Building walk, risk review, device layout and a bill of quantities you can check against competing quotes.
Supply
Panels, detectors, call points, sounders and beacons from manufacturers we can get spares for locally.
Installation
Containment, cabling, device mounting and panel wiring to the drawing, not improvised on site.
Programming
Cause-and-effect set up and tested — what sounds where, and what shuts down when.
Commissioning
Every device tested in the zone it protects, then a full functional test of the system.
Handover
As-built drawings, test results, staff training and a certificate for your file.
PANEL MAKES
The panels we install, service and fault-find.
Send us a photo of the panel door. The make and model usually tell us whether the part is on the shelf before we drive out.
✓ Gent by Honeywell
✓ Context Plus (C-TEC)
✓ Horing Lih
✓ INIM
✓ Cease Fire Italia
✓ Gent Nano
✓ Eaton
✓ Global
✓ Notifier
✓ EST / Edwards
✓ Siemens
✓ Hochiki
✓ Apollo
✓ Simplex
MAINTENANCE
The visit that keeps the certificate valid.
Panels sit quietly for years, then fail on the day they are needed — usually because a detector was never cleaned, a battery was never checked or a sounder circuit was never proven.
- Every device tested, not a sample
- Detectors cleaned and recalibrated
- Battery and charging circuit checked
- Sounder and beacon audibility confirmed
- Fault log reviewed and cleared
- Visit report and dated certificate issued
Fault rectification
Critical faults are attended within four hours on working days, and the fault line is answered 24/7 by technicians rather than a call centre.
We trace the circuit, repair or replace the device, then prove the zone works before leaving. The visit is logged either way.
AMC LEVELS
(Annual Maintenance Contract)
Two contract levels — pick by how much risk sits on the panel.
Both include records and priority response. The difference is how often we attend and how much parts cover includes.
- Scheduled visits: Two per year
- Every device tested: Yes
- Detector cleaning: On visit
- Battery replacement: Quoted
- Fault response: Next working day
- Parts allowance: Quoted per job
- Emergency Visits: Two
- Documentation: Visit report
- Scheduled visits: Quarterly
- Every device tested: Yes
- Detector cleaning: Every visit
- Battery replacement: Included when due
- Fault response: 4 hours, critical faults
- Parts allowance: Agreed annual allowance
- Emergency Visits: Five
- Documentation: Visit report + annual certificate
QUESTIONS
Fire alarm, asked before the first visit.
Can you fix a panel showing a fault?
Do you install new systems?
Will you maintain a system installed by someone else?
What does an annual maintenance contract include?
How long does an installation take?
Do you provide as-built drawings?
What about false alarms?
Do you cover factories and warehouses outside the city?
COVERAGE
Site visits across the city, and scheduled routes to the estates.
Our workshop sits inside the city rather than on its edge, so cylinders spend less time in a vehicle and more time being worked on. Outside the city, equipment ships by courier.
Industrial estates
Factories in Nooriabad, Jamshoro and the Hyderabad belt are served on a scheduled route rather than a same-day promise — the drive is roughly two hours each way. For plant-wide contracts we survey once and then run scheduled visits, so your team is not chasing several suppliers across a dozen buildings.
SITE
Korangi
Landhi
Port Qasim
Federal B Area
Gulshan-e-Iqbal
North Nazimabad
Gulistan-e-Johar
PECHS
Clifton
DHA
Saddar
Serai Road
Scheme 33
Shahrah-e-Faisal
Malir
Bahria Town
Airport
FREE SITE ASSESSMENT
Tell us what is on site. We will scope it in writing.
Send cylinder counts, panel make, or a photo of the label — that is usually enough to come back with a real number instead of a range.
● 021-32410018 ● 0333-2112463 ● info@fireflex.pk
Request a proposal
Same working day response, Mon–Sat.
● 021-32410018
● 0333-2112463 · 24/7
● info@fireflex.pk
NEED A DECISION TODAY?
Three ways to reach us, depending on what you need.
A fault at 2am and a new-installation quote are different problems — so they come in through different doors.
Talk to an engineer
Site surveys, system design and specifications. Someone who has actually been on a site, not a call center.
Request a proposal
Send cylinder counts, a panel photo or a floor plan and get a written scope back with the exclusions priced.
Fault line - 24/7
Critical alarm faults attended within four hours on working days. Panels, pumps and fault rectification.
Fire Flex
Fire safety and systems: refilling, alarm installation and maintenance contracts, equipment supply — for factories, offices and commercial buildings.
Coverage
- Karachi — all areas
- Hyderabad
- Nooriabad
- Jamshoro
Contact
- 021-32410018
- 0333-2112463
- info@fireflex.pk
- Office # 21, 2nd Floor, Sadaf Centre,
Serai Road, Karachi 74000 - Mon–Sat, 09:00–18:00 · fault line 24/7
© 2026 Fire Flex — Fire Safety & Systems Karachi · Hyderabad · Nooriabad